Site Plan Designer

Upload your floor plan, or start from our sample, and drop on over 50 kinds of equipment -- cameras, detectors, readers and doors, intercoms, fire devices, speakers, Wi-Fi, racks and more -- to see what each one covers. Get a cable schedule for each system -- CCTV, alarm, access control, intercom, fire, network and audio -- with lengths and the cable to order. Download it all as an Excel workbook, or save a picture or a plan file.

How it works

Set the scale by clicking two points a known distance apart. Cameras show the IEC 62676-4 (DORI) bands -- 25 px/m to detect, 62.5 to observe, 125 to recognise and 250 to identify -- from their resolution and field of view (2 x atan(sensor width / 2 x focal length), or the datasheet angle). Motion detectors show their range and angle. Ceiling speakers cover a circle of (ceiling height - listening height) x tan(half the coverage angle). Wi-Fi access points and other devices show the radius you enter. Each device is cabled to the nearest head end of its system (recorder, alarm panel, door controller, switch or rack, amplifier) along the walls and ceiling -- across, then along -- plus 4 m for drops and terminations and 10% spare.

Need help designing a system? Talk to our team, or see all 42 free calculators.